Dräger Atlantis and Dolphin semiclosed-rebreather

de
de

Dräger 90’s sportsrebreather semiclosed

In the mid-1990s, Dräger launched the Atlantis 1 semi-enclosed rebreather. Shortly afterwards, the model became the Dolphin rebreather. The rebreather was widely sold by a huge number of dealers which increased to a substantial market share a few years later. These two rebreathers certainly contributed to the success of the rebreather in the sports diving world in the Benelux. The simple design was later also widely used to be modified into closed MCCR systems. See the homebuilder section of my website for this.

Therebreathersite Atlantis 007

DATASHEET SEMICLOSED REBREATHER
Atlantis 1Date: 21 June 2006
Updated 2022
Predecessor of the DolphinDatabase semi closed rebreathers by: J.W. Bech
ManufacturerDräger(name or company)
Designer(name)
ModelAtlantis I(number type)
Land of originGermany(country)
Design year1994(actual project start)
Special Note: Predecessor of Dolphin(additional space for info)
User groupsportsdiving (sport/mil/civil/fire)
Magnetic characteristicsn.a.(if known)
Part no: (part #)
Working principleConstant Mass Flow(CMF/Metering,Passive)
Gas typeNitrox(Heliox/Nitrox)
Gasmix type% Oxygen% HeliumFlowWorktimeDepth
Pure Oxygen (no color)10001,4-2.0 barL/min470* (180)4
Nitrox60 (black)6005,8 barL/min12117
Nitrox50 (red)5007,3 barL/min9622
Nitrox40 (blue)40010,4 barL/min6730
Nitrox32 (yellow)32015,6 barL/min4540
 
Intended useSportSport/MC/Deep/Tethered
Dimensions LxWxH340x435xdepth190 mm(outside in mm)
Device weight17 kg(filled+gas on land)
Intermediate Pressure40 bar(IP )
Overpressure valve18-25 mbarRange
Max depth40(mtrs)
Used material for housing/backplateABS 
Pressure reducerMembrane typeMembrane / Mushroom
Connection reducer – bottlesM24x2 EN144-2 
Supply pressure200 bar, minimum 20 bar 
Umbilical connectionNo 
Manual bypassNo 
pO2 measurement standardNo 
Pressure gauge range0-250 bar 
Cylinders4 or 5  litre 
Cylinder materialSteel 
Cylinder threadG ? 
ValveM24x2 
Designed for gasmixNitrox 
Co2 absorption cartridge capacity2,3 liter 
Co2 absorption cartridge rechargeableYes 
Co2 absorption cartridge storagetemp-20ºC to 50 ºC 
Co2 absorption time testing (CE)Yes 
Connections Co2 cartridgeP-connectors 
Guaranteed absorption time2,5 hours 
Grade of absorption materialDrägersorb 
Breathing bag material  
Inhale bag volume7,1 ltr (inhale+exhale) 
Exhale bag volume  
Total loop VolumeTotal volume 10,5 liter 
Operating temperature15ºC to 25 ºCWhen used in temperatures below 10ºC the scrubber material should be stored at room temperature during 12 hours and the scrubber filled direct before the dive!
Magnetic signaturen.a. 
Colour (s)Blue/White 
WornOn the back 
FFM attachedNO(mask)
Mouthpiece valveYes 
Extra info:160 NPositive wing buoyancy
Additional information:  
Email address owner:  
URL owner:  
If you have any information to add this sheet please mail it to jw.bech@quicknet.nl References to source and names will always be added!   
Info found: 
Origin: http://www.therebreathersite.nl 
Info: 
 
The Atlantis (and early types of the Dolphin) were delivered with a doses measuring device. Duration for dosage testing where: 60% oxygen content, lower limit 184 seconds upper limit 250 seconds.
50% oxygen content, lower limit 147 seconds upper limit 196 seconds.
40% oxygen content, lower limit 97 seconds upper limit 135 seconds.
32% oxygen content, lower limit 72 seconds upper limit 90 seconds.
 
Therebreathersite Atlantis 009

Measuring the gasflow using the standard measuring device
For this test, take the volume flow test device (41) or another suitable volume flow measuring device and connect it to the quick coupling (48) with the bypass valve. A mixing gas cylinder containing the relevant mixture for the volume flow to be tested with at least 50 bar filling pressure must be connected to the reducing valve. The test device must lie on a horizontal surface and move freely during the test. Breathe through the housing of the safety valve (49) to completely empty the test device and then monitor it for approx. 20 s. No leakage should occur and the bag of the test device should remain folded together. Then fill the housing of the safety valve up to the fill mark (43) with water. You should hold the housing upright in your hand during the entire measurement. Now open the mixing gas bottle and start the time measurement at the same time. Measure the time until the first gas bubbles emerge from the water-filled reducing valve. The measured times should be within the values listed in Table 6.1.1.    
 
Therebreathersite Atlantis 005

  Mengsel Onderste grenswaarde Bovenste grenswaarde 60% O2/40% N2 184 s 250 s 50% O2/50% N2 147 s 196 s 40% O2/60% N2 97 s 135 s 32% O2/68% N2 72 s 90 s  
Checking the volume flow with the Dwyer ball flowmeter The Dolphin rebreather can also be supplied with the compact Dwyer MMA Series Mini Master ball flow meter. Two types of flowmeters are available from Dräger. With the first type, the scale runs from 0-25 litres/minute and with the second type, a coloured area indicates the range within which the output of a particular nozzle should lie. Both types are universal flow meters (i.e. not specifically made for the Dolphin) and are therefore suitable for measurements at both pressure and vacuum. As a rule, these flow meters are therefore supplied unassembled so that the user can assemble the meter himself for his specific application. To do this responsibly, the supplier (Dwyer) has enclosed clear assembly instructions for this purpose. For our specific application, we recommend building up the flow meter for working with overpressure with a control valve in the lower connection.This control valve allows the gas supply to increase in a controlled manner until the maximum volume flow is reached. This prevents the so-called “dancing” of the ball that occurs when the flow meter is suddenly pressurised.  When measuring, ensure that the flow meter is held in perpendicular position and the control valve is fully open while reading the volume flow.
 

Therebreathersite Atlantis 011
 
Failure to adhere to this warning may result in serious injury and death. If the measured values are outside the specified ranges you should check whether you have made a mistake and perform the measurement again accurately in accordance with the operating instructions. If the value is then still outside the specified range then take the device to an authorised professional. After the volume flow test has been completed, close the mixing gas cylinder and wait until the pressure in the middle and high pressure range is zero (no pressure indication on the manometer). After closing the mixing gas cylinder, the indication on the manometer should decrease evenly. If this is not the case, the pressure gauge must be checked by a specialist. Pour the water out of the safety valve housing and disconnect the connection between the test device and the bypass valve. If you want to test the regulators with a suitable float meter (suitable for mixed gas), the volume flows must be in the following ranges (table 6.1.2):   Mix vol-% O2 / vol-% N2 Lower value (L / min) Higher Value (L / min) 60/40 5,1 6,4 50/50 6,55 7,95 40/60 9,4 11,3 32/68 14,2 16,9   Photos and text thanks to Tino de Rijk and Rita Oosterbaan IANTD instructors Netherlands.


1
Dolphin 002
Dolphin 003
Dolphin 004
Therebreathersite Atlantis 001
Therebreathersite Atlantis 002
Therebreathersite Atlantis 003
Therebreathersite Atlantis 008

JW

Therebreathersite was founded by Jan Willem Bech in 1999. After a diving career of many years, he decided to start technical diving in 1999. He immediately noticed that at that time there was almost no website that contained the history of closed breathing systems. The start for the website led to a huge collection that offered about 1,300 pages of information until 2019. In 2019, a fresh start was made with the website now freely available online for everyone. Therebreathersite is a source of information for divers, researchers, technicians and students. I hope you enjoy browsing the content!