1918 Draegerogen models 1916 and 1918/1926 and 1928

Database German Oxygen rebreathers

This page shows the 1916 designed Drägerogen, produced in 1918, relaced by model 1916/1926 and model 1928

Drägerogen model 1916. Designing the first of Dräger’s device with chemically bound oxygen based on sodium and potassium peroxides. After the 1916 model it was followed by other improved types, such as the 1918 (1 hour) and 1926 models(2 hour). In 1928 it was possible to equip the miners working in front of the coalmine with self-rescue gas protection devices. The gas protection device Drägerogen model 1928 was suitable for this purpose and replaced the model 1918/26 for 50 minutes of use.  This was an alkaline peroxide breathing apparatus with an oxygen-supplying proxylene chemical cartridge. It weighed 4.3 kg at 45 minutes of use

Picture3

Picture2

Picture1

As you can see, hardly any information about the Drägerogen type of breathing apparatus is available on my website anymore. All information about this respirator is welcome. Please send it to me so I can add it to the history of this device!


The following text was found in a sales catalogue of Inhabad Gmbh. For years, Inhabad was in fierce competition with Draeger. It is therefore not surprising that a sales brochure explained in detail why the Draeger Draegerogen apparat was not good.

From ‘Der Neue Weg Zum Sauerstof’ Inhabad GMBH Berlin NW6;

Proxylen-Geräte: (Deutscher Originaltext)

Auf einem ähnlichen Prinzip beruhte das zunächst von der Hanseatischen Apparatebaugesellschaft, Kiel, in de Handel gebrachte Proxylen-Gerät, an das sich das vom Drägerwerk Lübeck herausgebrachte Draegerogen-Gerät anschloss. Beide (Pneumatogen Neupert Wien 1905) unterschieden sich im wesentlichen nicht. Auch diese beide Geräte haben sich nicht eingeführt, trotzdem die versuche, besonders auch von den deutschen Behörden, während des Krieges, in grösstem Massstabe gefördert wurden.

Das Drägerwerk schreibt über das Gerät in Nr. 112 der Drägerhefte (September 1926): ,,Das Chemicalpräparat des Draegerogen lieferte nach 2 minuten dauernder Anatmung eine Sauerstoffmenge, die zur Aufrechterhaltung der Atmung bei langsamem Marsch (!) ausreichte. Aus Sicherheitsgründen wurde dem Gerät die Vorschrift beigegeben: Vor Gebrauch 5 minuten anatmen! Die verbreitung dieses Gerätes wurde vom Drägerwerk nicht mit Nachdruck gefördert, weil eine Atmungspause keineswegs in jedem Arbeitsfall in Kauf genommen werden kann”.*) Das Gerät springt also zu langsam an (wenn man das vorgeschriebene Durchpusten der Patrone und das Wiedereinsetzen mitrechnet, erst nach etwa 5 minuten), und die Sauerstoffzufuhr, die nur zur Aufrechterhaltung der Atmung bei langsamen Marsch ausreicht, ist für Arbeitszwecke zu gering. Die Atmungswiderstände nehmen infolge starken Aufblähens des Chemicals schnell zu, die Einatmungstemperatur steigt bei normaler Aussentemperatur bis auf 50 grad C. Bei ein Aussentemperatur van 0 grad C. und weniger ist das Gerät nicht verwendbar, da die Sauerstoffabgabe aufhört. Ein weiterer Nachteil des Gerätes ist, dass es leicht Sauerstoff liefert, der mit ätzenden Natriumsuperoxydteilchen durchsetzt ist und somit für die Atmung gefährlich werden kann.

*) Draegerheft Nr 135 (1929) hat sich das Draegerwerk entschlossen, das Draegerogengerät aus dem Handel zurückzuziehen.

Proxylene devices: (German original text)

The Proxylen device, initially marketed by Hanseatische Apparatebaugesellschaft, Kiel, was based on a similar principle and was followed by the Draegerogen device published by Drägerwerk Lübeck. Both (Pneumatogen Neupert Vienna 1905) were essentially the same. These two devices did not become widely used either, despite the fact that attempts were promoted on a large scale during the war, especially by the German authorities.

Drägerwerk writes about the device in No. 112 of the Drägerhefte (September 1926): The chemical preparation of the Draegerogen supplied an amount of oxygen after 2 minutes of breathing which was sufficient to maintain breathing during a slow march (!). For safety reasons, the instructions were included with the device: Breathe for 5 minutes before use! The distribution of this device was not actively promoted by the Drägerwerk, because a breathing pause is by no means acceptable in every work situation”.*) The device therefore starts too slowly (if you include the prescribed blowing through of the cartridge and reinsertion, only after about 5 minutes), and the oxygen supply, which is only sufficient to maintain breathing during slow marches, is too low for working purposes. The respiratory resistance increases rapidly as a result of the strong inflation of the chemicals, and the inhalation temperature rises to 50 degrees C at normal outside temperatures. At an outside temperature of 0 degrees C. and below, the unit cannot be used, as oxygen delivery stops. Another disadvantage of the device is that it easily delivers oxygen that is interspersed with corrosive sodium peroxide particles and can therefore be dangerous for breathing.

*) Draegerheft Nr 135 (1929) the Draegerwerk has decided to withdraw the Draegerogen device from the trade.


JW

Therebreathersite was founded by Jan Willem Bech in 1999. After a diving career of many years, he decided to start technical diving in 1999. He immediately noticed that at that time there was almost no website that contained the history of closed breathing systems. The start for the website led to a huge collection that offered about 1,300 pages of information until 2019. In 2019, a fresh start was made with the website now freely available online for everyone. Therebreathersite is a source of information for divers, researchers, technicians and students. I hope you enjoy browsing the content!